Specifications
| Characteristic | Specification | Configuration |
| Pos Opt | ||
| Working direction | from Left to Right | √ |
| Height of glass plates | 350 mm – 2.700 mm | √ |
| Length of glass plates | 450 mm – 5.000 mm (2 x press up to 5.5m) | √ |
| Thickness of glass plates | 3 mm – 15 mm | √ |
| Thickness of I.G. units | 12 mm – 60 mm | √ |
| Maximum unit weight | 300 kg/m, 1.200 kg/unit | √ |
| Spacer Width (SW) | 6 mm – 24 mm | √ |
| Joint depth | 4 mm – 20 mm | √ |
| Types of I.G. units | Rectangular units | √ |
| Double units | √ | |
| Triple units | √ | |
| 1-3 stepped units | √ | |
| Plant inclination | 6,0° | √ |
| Height of glass support level – vertical. | 520 mm (± 20 mm) | √ |
| Gas filling rate | 90% | √ |
| Electrical tension and frequency | 415V (+6% / -10%) / 50 Hz / 3 Phases (+N, +PE) | √ |
| General conveying speed | 48 m/min | √ |
| Speed of washing machine | 4-12 m/min | √ |
| Color / Paint | -Design | √ |
| Language of manuals and labelsLanguage at Operator panel | English and ChineseEnglish and Chinese | √ |
| √ | ||
| Requirements for processing glass plates | ||
| Processable glass types | Float, toughened glass, laminated glass, patterns (only partially possible; depending on glass surface and position of the structure) | |
| Flatness tolerance of glass plates | Deviation from ideal plane of the entire glass plate may not exceed 2 mm. | |
| Greater deviations can lead to disturbances to the job routing and require a functional intervention from case to case through the operating personel. | ||
| Cutting tolerance of glass plates | +/- 0,5 mm A glass plate congruence of +/- 0,5 mm must be both with shapes and with rectangular formats guaranteed. | |
| Laminated glass | preferably rectangular sawn or ground, no overhanging foils | |
| Glass edges | cut, without bevels | |